All Passy-Muir® Tracheostomy and Ventilator Swallowing and Speaking Valves have a closed position "No Leak" design that restores a closed respiratory system. The patented "No Leak" design of the Passy-Muir Valves means that the valve is always in a closed position until the patient inhales. The valve opens easily with less than normal inspiratory pressures and closes automatically at the end of the inspiratory cycle without air leak and without patient expiratory effort. Passy-Muir Valves are the ONLY speaking valves FDA indicated for all of the following uses:
- Communication
- Improves Swallowing
- May Reduce Aspiration
- Ventilator Application
- Improves Olfaction
- Improves Oxygenation
|
- Facilitates Secretion Management
- Expedites Weaning & Decannulation
- Restores Positive Airway Pressure
- Facilitates Infection Control
- Interchangeability Between Tracheostomy and Ventilator Use
|
Passy-Muir® Low Profile Tracheostomy & Ventilator Swallowing and Speaking Valve (clear)
Closed Position "No Leak" valve for adult, pediatric and neonatal patients.
- Less visible for more ambulatory patients. More commonly used by non-ventilator patients but can also be used in-line with mechanical ventilators with a 22mm silicone adapter.
- Comes with one PMV® Secure-It®.
| MFR # |
DESCRIPTION |
UNIT |
HCPCS |
| PMV2000 |
15mm I.D./23mm O.D. |
each |
L8501 |
Passy-Muir® Low Profile Tracheostomy & Ventilator Swallowing and Speaking Valve (Purple Color™)
Closed Position “No Leak” valve for adult, pediatric and neonatal patients.
- More visible for inpatient use. More commonly used by non-ventilator patients but can also be used in-line with mechanical ventilators with a 22mm silicone adapter.
- Comes with one PMV® Secure-It®.
| MFR # |
DESCRIPTION |
UNIT |
HCPCS |
| PMV2001 |
15mm I.D./23mm O.D. |
each |
L8501 |
Passy-Muir® Tracheostomy & Ventilator Swallowing and Speaking Valve (Aqua Color™)
Closed Position “No Leak” valve for adult, pediatric and neonatal patients.
- Designed for ventilator application with adult disposable ventilator tubing. An adapter may be needed to use this valve in-line with pediatric or closed suctioning systems.
- Can also be used off the ventilator.
| MFR # |
DESCRIPTION |
UNIT |
HCPCS |
| PMV007 |
15mm I.D./22mm O.D. |
each |
L8501 |
Passy-Muir® Valve Oxygen Adapter
- Snaps onto PMV® 2000 (clear) and PMV® 2001 (Purple Color™) for easy delivery of supplemental low flow oxygen (<6L/min) and humidity.
- Avoids complications (air trapping, drying of secretions, cilia damage) by delivering oxygen in front of diaphragm.
| MFR # |
DESCRIPTION |
UNIT |
HCPCS |
| PMA2000 |
Oxygen Adapter |
each |
E1399 |
|