CPAP Information

Menu

Ventilator Information

Jump to:

Newport Medical

Sun Med

HT70® Ventilator Test Lung

Newport Medical

The Newport HT70® Ventilator combines ease of use, clinical finesse, exceptional portability, and ruggedness in one compact package.

Designed for patients ≥ 5kg to adult, the HT70 is ideal for home care, transport, hospital, longterm care, and emergency preparedness applications for invasive or noninvasive ventilation. The full color touch screen is easy to navigate and offers specific screens for homecare, transport and hospital applications, default or customizable presets, Alarm Quickset and Help functions.

Developed and manufactured entirely by Newport Medical in California, USA, the compact HT70 features a newly designed, patented, micro-piston technology that eliminates the need for external compressed gas. The hot swappable integrated battery system provides up to 10 hours of operation at standard settings and can be fully recharged in only 3 hours. For a long transport, a full day at the park or in case of a power emergency , the HT70 allows for virtually continuous operation.

Modes (Pressure or Volume)

A/CMV

 

SIMV

 

SPONT

NIV (non-invasive ventilation)

available in all modes

VT (Tidal Volume)

50 to 2,200 mL

RR (Respiratory Rate)

1 to 99 b /min

i Time (Inspiratory Time)

0.1 to 3.0 sec

PEEP/CPAP

0 to 30 cmH 2 O/0 to 30 mbar

PS (Pressure Support)

0 to 60 cmH 2 O/0 to 60 mbar *

Flow

6 to 100 L/min

I:E Ratio

1:99 to 3:1

PC (Pressure Control)

5 to 60 cmH 2 O/5 to 60 mbar

Ptrig (Sensitivity)

-9.9 to 0 cmH 2 O/-9.9 to 0 mbar

Manual Inflation

3 sec maximum

F I O 2 (Optional) +

.21 to 1.00

Bias Flow

7 L/min with PEEP

3 to 30 L/min (when NIV is On)

PS Max i time

0.1 to 3.0 sec

PS % Exp. Threshold

5 to 55%

Slope Rise

1 to 10

Flow Wave Pattern

square or descending

Auto Lock function

ON / OFF

Language Selection

multiple language options

Remote Alarm

Normally Open or Closed

*PEEP + PS cannot exceed 60 cmH2O/mbar

   
Monitored Parameters

 

Paw (Peak, Mean, Base)

VT I (insp. tidal volume)

MV I (insp. minute volume)

Peak Insp. Flow

Integrated Battery Pack

RR tot (total respiratory rate)

Back up internal battery

I:E Ratio

F I O 2 +

 

   
Alarms

 

High Airway Pressure

Low Airway Pressure

High Baseline Pressure

Low Baseline Pressure

High Resp. Rate

Back-up Ventilation Alert

High Insp. Minute Volume

Low Insp. Minute Volume

Apnea

 

High F I O 2 +

Low F I O 2 +

Device Alert

Low Battery

 

+ Only available with optional O2 Sensor installed


Specialty Screens
Events

Record up to 1,000 events.

Parameter settings for each event are recorded
Trends

Displays trend graphs for last

72 hours
Help

Touch any button for a tutorial of

that feature
Domains Basic, transport and hospital
Download Data Capture and download events
Patient Presets Customized or Default
Customized Back Up Ventilation Link with Apnea and/or Low MV I and customize settings

 

Sun Med

Test LungTEST LUNG

Used for demonstrating and testing ventilator equipment. Medium Test Lung 500 to 750cc

Latex free Order Respiratory Equipment
Foam filled
Superior quality

Autotitration | Apnea Monitors | CoughAssist | CPAP Devices | Stationary and Portable Oxygen Concentrators
Liquid Oxygen | Medical Oxygen - Portable/Emergency | Oxygen Conserving Regulators
Pulse Oximeters | Ventilators, Transport/Portable
 |  954-941-1288  |  800-650-5953
1829 South Dixie Highway | Pompano Beach, Florida 33060
© 2004 - 2011 Southeast Oxygen  |  All trademarks belong to their respective corporations